Vötsch VT 7030 S2 thermal shock test chamber, 300 l environmental test chamber TS05Vötsch
VT 7030 S2
Vötsch VT 7030 S2 thermal shock test chamber, 300 l environmental test chamber TS05
Vötsch
VT 7030 S2
VB ditambah cukai perkhidmatan
€12,184
Keadaan
Terpakai
Lokasi
Borken 

Data asas
Harga & Lokasi
VB ditambah cukai perkhidmatan
€12,184
- Lokasi:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Hubungi
Butiran tawaran
- ID iklan:
- A18910781
- Nombor rujukan:
- 46212
- Kemas kini:
- terakhir pada 21.10.2026
Penerangan
Vötsch VT 7030 S2 Temperature Shock Test Chamber
System for extreme temperature changes
During temperature shock testing, the resistance of components, devices, and other products to rapid changes in ambient temperature is tested.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
By means of these cyclic loads and the accelerated aging caused by temperature changes, weaknesses in the test specimen can be identified.
Bedewbdv Sopfx Apmeww
Vertical arrangement of the test chambers
Ball screw drive for secure guidance of the carriage
All-round grids in the carriage secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
The warm chamber can be used as a temperature storage device, and the cold chamber as a temperature change device
Touch panel for convenient operation of the simulation programs with graphical display
Minimal energy consumption
No compressed air required
Data for temperature tests in single-chamber operation
Warm chamber:
Temperature shock test chamber, test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation over time in the center of the usable space ± 1 K
Temperature deviation spatially ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in the supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber, test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation over time in the center of the usable space ± 1 K
Temperature deviation spatially 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in the supply air)
Heating 1.5 K/min
Cooling 4 K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 %, 50 Hz
Nominal power: 30 kW
Nominal current: 50 A
Refrigerant: R-404a /R-23
Refrigeration unit: Water-cooled
Weight: approx. 940 kg
Year of manufacture: 1998
Test chamber dimensions: Width 770 mm x Depth 650 mm x Height 610 mm
Housing dimensions: Width 1200 mm x Depth 1800 mm x Height 2050 mm
TS 05
You can find more new and used items in our shop! International shipping costs on request!
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
System for extreme temperature changes
During temperature shock testing, the resistance of components, devices, and other products to rapid changes in ambient temperature is tested.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
By means of these cyclic loads and the accelerated aging caused by temperature changes, weaknesses in the test specimen can be identified.
Bedewbdv Sopfx Apmeww
Vertical arrangement of the test chambers
Ball screw drive for secure guidance of the carriage
All-round grids in the carriage secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
The warm chamber can be used as a temperature storage device, and the cold chamber as a temperature change device
Touch panel for convenient operation of the simulation programs with graphical display
Minimal energy consumption
No compressed air required
Data for temperature tests in single-chamber operation
Warm chamber:
Temperature shock test chamber, test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation over time in the center of the usable space ± 1 K
Temperature deviation spatially ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in the supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber, test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation over time in the center of the usable space ± 1 K
Temperature deviation spatially 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in the supply air)
Heating 1.5 K/min
Cooling 4 K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 %, 50 Hz
Nominal power: 30 kW
Nominal current: 50 A
Refrigerant: R-404a /R-23
Refrigeration unit: Water-cooled
Weight: approx. 940 kg
Year of manufacture: 1998
Test chamber dimensions: Width 770 mm x Depth 650 mm x Height 610 mm
Housing dimensions: Width 1200 mm x Depth 1800 mm x Height 2050 mm
TS 05
You can find more new and used items in our shop! International shipping costs on request!
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Didaftarkan sejak: 2008
531 Iklan dalam talian
Hantar permintaan
Telefon & Faks
+49 2862 ... iklan
Iklan anda telah berjaya dipadamkan
Berlaku ralat
















