Ruang ujian suhu -40°C hingga +180°CVötsch
VT 4004
Ruang ujian suhu -40°C hingga +180°C
Vötsch
VT 4004
Keadaan
Terpakai
Lokasi
Borken 

Gambar menunjukkan
Tunjukkan peta
Data mesin
- Nama mesin:
- Ruang ujian suhu -40°C hingga +180°C
- Pengeluar:
- Vötsch
- Model:
- VT 4004
- Keadaan:
- sangat baik (terpakai)
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, DE

Hubungi
Butiran tawaran
- ID iklan:
- A20438740
- Nombor rujukan:
- 24863
- Kemas kini:
- terakhir pada 03.11.2025
Penerangan
Type: VT 4004
Vötsch Temperature Test Chamber, Air-Cooled
Temperature Range: -40°C to +180°C
37 liters
Temporal Temperature Fluctuation in the Usable Volume: ±0.2 K to 0.5 K
Spatial Temperature Deviation: ±0.5 K to 1.5 K, corresponding to a temperature gradient of 1 K to 3 K
Temperature Rate:
Temperature change rate according to IEC 60068-3
Heating: 5.3 K/min
Cooling: 6.0 K/min
Heat compensation: max. 550 W
Calibration values: +23°C and +80°C
Technical Description VTM 4004
Installation and Operation Data:
Test chamber internal dimensions: Width 320 mm, Depth 290 mm, Height 400 mm
External dimensions: Width 1000 mm, Depth 780 mm, Height 630 mm
Test Chamber:
Floor load capacity: 200 kg/m²
Point load: max. 15 kg
Test chamber lighting:
Halogen lamp 20 W, only with additional equipment “door with viewing window”
Port openings:
3x port openings
2x diameter 50 mm, installed left side
1x diameter 80 mm, installed left side
Refrigeration unit: low-noise, fully hermetic refrigeration, air-cooled
Control terminal:
Mincontrol
Backlit display
Plain text display
Password protection
Input for setpoints; access to stored test programs
Temperature limiting software for minimum and maximum chamber temperatures
Plain text error messages
Control system:
Microprocessor-controlled regulation and monitoring system MINCON/32
32-bit technology
Integrated program controller
Fault diagnostic system
Program memory for 100 programs with a total of 1000 segments,
250 loops and 9999 cycles
RS 232 interface
Communication with user’s PC
Networking of up to 32 devices optionally possible via RS 485
Voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 0.7 kW Rated current: 4.0 A
Refrigerant: R-404A
Weight: 115 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out in advance on chambers offered by us:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data and details subject to change and errors)
Blsdpjxt D Ayofx Af Ijp
If you have further questions, we will be pleased to answer them by phone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Vötsch Temperature Test Chamber, Air-Cooled
Temperature Range: -40°C to +180°C
37 liters
Temporal Temperature Fluctuation in the Usable Volume: ±0.2 K to 0.5 K
Spatial Temperature Deviation: ±0.5 K to 1.5 K, corresponding to a temperature gradient of 1 K to 3 K
Temperature Rate:
Temperature change rate according to IEC 60068-3
Heating: 5.3 K/min
Cooling: 6.0 K/min
Heat compensation: max. 550 W
Calibration values: +23°C and +80°C
Technical Description VTM 4004
Installation and Operation Data:
Test chamber internal dimensions: Width 320 mm, Depth 290 mm, Height 400 mm
External dimensions: Width 1000 mm, Depth 780 mm, Height 630 mm
Test Chamber:
Floor load capacity: 200 kg/m²
Point load: max. 15 kg
Test chamber lighting:
Halogen lamp 20 W, only with additional equipment “door with viewing window”
Port openings:
3x port openings
2x diameter 50 mm, installed left side
1x diameter 80 mm, installed left side
Refrigeration unit: low-noise, fully hermetic refrigeration, air-cooled
Control terminal:
Mincontrol
Backlit display
Plain text display
Password protection
Input for setpoints; access to stored test programs
Temperature limiting software for minimum and maximum chamber temperatures
Plain text error messages
Control system:
Microprocessor-controlled regulation and monitoring system MINCON/32
32-bit technology
Integrated program controller
Fault diagnostic system
Program memory for 100 programs with a total of 1000 segments,
250 loops and 9999 cycles
RS 232 interface
Communication with user’s PC
Networking of up to 32 devices optionally possible via RS 485
Voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 0.7 kW Rated current: 4.0 A
Refrigerant: R-404A
Weight: 115 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out in advance on chambers offered by us:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data and details subject to change and errors)
Blsdpjxt D Ayofx Af Ijp
If you have further questions, we will be pleased to answer them by phone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Didaftarkan sejak: 2012
Hantar permintaan
Telefon & Faks
+49 2861 ... iklan
Iklan anda telah berjaya dipadamkan
Berlaku ralat