Unit Penyejuk Suhu (TCU)Single
Water Advanced WP7
Unit Penyejuk Suhu (TCU)
Single
Water Advanced WP7
Keadaan
Baharu
Lokasi
Hochdorf 

Gambar menunjukkan
Tunjukkan peta
Data mesin
Harga & Lokasi
- Lokasi:
- Ostring 17-19, 73269 Hochdorf, Deutschland

- penyewaan:
- adalah mungkin
Hubungi
Butiran tawaran
- ID iklan:
- A6050776
- Nombor rujukan:
- Water Advanced WP7
- Kemas kini:
- terakhir pada 21.11.2024
Penerangan
*TECHNICAL SPECIFICATION:
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/minÂ
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mmÂ
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control box IP54, externally ventilated
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Hsdog Ey T Ejpfx Abdsnw
Visit our website for more details or for other performance classes.
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/minÂ
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mmÂ
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control box IP54, externally ventilated
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Hsdog Ey T Ejpfx Abdsnw
Visit our website for more details or for other performance classes.
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Hantar permintaan
Telefon & Faks
+49 170 6... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
iklan kecil
Weert
10,091 km
Robot industri
ABBIRB6640-235/2.55 IRC5
ABBIRB6640-235/2.55 IRC5
iklan kecil
Bilbao
10,892 km
LHDN 2400-16 IRC5
ABBIRB 2400-16 IRC5
ABBIRB 2400-16 IRC5
iklan kecil
Hochdorf
9,850 km
Unit Penyejuk Temperatre (TCU)
SingleOil Advanced D2
SingleOil Advanced D2
iklan kecil
Austria
9,385 km
Sistem meja kimpalan 3D dengan pelarasan ketinggian
KK KletzerSchweißtisch SWT 65-105/16M Ø 28 Flex 2480x1230
KK KletzerSchweißtisch SWT 65-105/16M Ø 28 Flex 2480x1230
iklan kecil
Brieselang
9,582 km
Khemah pereka
Shelt Air
Shelt Air
iklan kecil
Suffolk
10,408 km
Termoformer multivac untuk bahagian 14g dan 20g
MultivacR245
MultivacR245
iklan kecil
Jerman
11,348 km
Mesin pengacuan suntikan melebihi 5000 KN
KraussMaffeiKM-650-3500 C-2
KraussMaffeiKM-650-3500 C-2
iklan kecil
Skarżysko-Kamienna
9,032 km
Stesen air demineral
ROMERRDI-2 / RDI-4
ROMERRDI-2 / RDI-4
iklan kecil
Contamine-sur-Arve
10,114 km
Mesin EDM wayar
AGIECUT 20P
AGIECUT 20P
iklan kecil
Ystad
9,517 km
Pembungkusan
REEPAKREEFLOW 250
REEPAKREEFLOW 250
Iklan anda telah berjaya dipadamkan
Berlaku ralat