Penerangan
RS Simulators
RS Simulators ST2K 320/70D
Water-cooled Shock Test System
For sale is a high-performance thermal shock test system, model ST2K 320/70D.
This unit is ideally suited for standardized thermal shock testing
according to DIN EN 60068‑2‑14, including optional humidity testing in the upper test chamber.
With its two temperature chambers (–70 °C to +240 °C) and automatic test basket transfer, this system provides the perfect solution for component, material, and reliability testing in industry, research, and quality assurance.
Main technical data:
Temperature ranges:
Upper test chamber: +40 °C to +240 °C
Temporal deviation: ±0.8 K (per DIN 50011, empty chamber)
Lower test chamber: –70 °C to +240 °C
Temporal deviation: ±0.8 K (per DIN 50011, empty chamber)
Optional humidity test – Upper test chamber:
Temperature: +40 °C to +90 °C
Relative humidity: 20% to 98% r.h. (±2–5%)
Test basket transfer:
Vertical movement, < 10 seconds changeover time
Power supply:
Total power: 16 kVA
Current consumption: 32 A
Main fuse: 3 × 35 A slow-blow
Mains connection: 3 × 400 V / N / PE / 50 Hz
Main cable: 5 × 16 mm²
Water & compressed air connections:
Cooling water inlet: G ¾", approx. 3 bar, max. 10 bar / max. 15 °C
Cooling water requirement: max. 1.4 m³/h
Cooling water return: G ¾", max. 25.2 °C
Condensate drains: 2 × G ½", 1 × G ¼", unpressurized
Ibjdswx Ip Dspfx Abdjd
Deionized water inlet: G ⅜", approx. 3 bar, max. 6 bar
Compressed air connection: Quick coupling NW 7.2 (G ¼"), min. 4 bar, max. 10 bar
Dimensions & weight:
Test basket internal dimensions (Type ST2K 320):
Internal dimensions: Width approx. 430 mm, Height approx. 470 mm, Depth approx. 700 mm
External dimensions: Width: approx. 1100 mm, Height: approx. 2300 mm, Depth: approx. 2300 mm
Weight: approx. 1150 kg
Other technical data:
Sound level: approx. 60 dB(A) at 1 m distance (free field)
Refrigerants:
R-404A: approx. 2.5 kg (GWP 3800, limit value 0.48 kg/m³)
R-23: approx. 0.8 kg (GWP 12100, limit value 0.68 kg/m³)
Permissible operating environment:
Temperature: +12 °C to +30 °C
Humidity: 25%–75% r.h.
For your safety as the buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and details subject to change and errors reserved!)
We are happy to answer further questions by phone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
RS Simulators ST2K 320/70D
Water-cooled Shock Test System
For sale is a high-performance thermal shock test system, model ST2K 320/70D.
This unit is ideally suited for standardized thermal shock testing
according to DIN EN 60068‑2‑14, including optional humidity testing in the upper test chamber.
With its two temperature chambers (–70 °C to +240 °C) and automatic test basket transfer, this system provides the perfect solution for component, material, and reliability testing in industry, research, and quality assurance.
Main technical data:
Temperature ranges:
Upper test chamber: +40 °C to +240 °C
Temporal deviation: ±0.8 K (per DIN 50011, empty chamber)
Lower test chamber: –70 °C to +240 °C
Temporal deviation: ±0.8 K (per DIN 50011, empty chamber)
Optional humidity test – Upper test chamber:
Temperature: +40 °C to +90 °C
Relative humidity: 20% to 98% r.h. (±2–5%)
Test basket transfer:
Vertical movement, < 10 seconds changeover time
Power supply:
Total power: 16 kVA
Current consumption: 32 A
Main fuse: 3 × 35 A slow-blow
Mains connection: 3 × 400 V / N / PE / 50 Hz
Main cable: 5 × 16 mm²
Water & compressed air connections:
Cooling water inlet: G ¾", approx. 3 bar, max. 10 bar / max. 15 °C
Cooling water requirement: max. 1.4 m³/h
Cooling water return: G ¾", max. 25.2 °C
Condensate drains: 2 × G ½", 1 × G ¼", unpressurized
Ibjdswx Ip Dspfx Abdjd
Deionized water inlet: G ⅜", approx. 3 bar, max. 6 bar
Compressed air connection: Quick coupling NW 7.2 (G ¼"), min. 4 bar, max. 10 bar
Dimensions & weight:
Test basket internal dimensions (Type ST2K 320):
Internal dimensions: Width approx. 430 mm, Height approx. 470 mm, Depth approx. 700 mm
External dimensions: Width: approx. 1100 mm, Height: approx. 2300 mm, Depth: approx. 2300 mm
Weight: approx. 1150 kg
Other technical data:
Sound level: approx. 60 dB(A) at 1 m distance (free field)
Refrigerants:
R-404A: approx. 2.5 kg (GWP 3800, limit value 0.48 kg/m³)
R-23: approx. 0.8 kg (GWP 12100, limit value 0.68 kg/m³)
Permissible operating environment:
Temperature: +12 °C to +30 °C
Humidity: 25%–75% r.h.
For your safety as the buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and details subject to change and errors reserved!)
We are happy to answer further questions by phone.