RS-Simulator ST2K 1000/55 Peranti Kejutan Suhu -70°C hingga +180°C 580 LiterRS-Simulatoren
RS ST2K 1000/55
RS-Simulator ST2K 1000/55 Peranti Kejutan Suhu -70°C hingga +180°C 580 Liter
RS-Simulatoren
RS ST2K 1000/55
Keadaan
Terpakai
Lokasi
Borken 

Data asas
Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Butiran tawaran
- ID iklan:
- A21817508
- Nombor rujukan:
- 25175
- Kemas kini:
- terakhir pada 15.10.2026
Penerangan
RS Simulators
RS Simulators ST2K 1000 / 55
Temperature Shock Chamber
Water-cooled
The unit was regularly serviced and maintained by the manufacturer until it was decommissioned.
For sale is a high-performance temperature shock test chamber, type ST2K 1000 / 55.
The unit is ideal for standard-compliant thermal shock tests in accordance with DIN EN 60068-3-5, as well as for demanding material and component tests.
With its two separate temperature chambers and automatic horizontal test basket transfer, this unit offers the perfect solution for reliability tests in industry, automotive, research and quality assurance.
Key technical data:
Temperature ranges
Upper test chamber (hot chamber): +40 °C to +180 °C
Time deviation: ±0.8 K (according to DIN 50011, empty chamber)
Lower test chamber (cold chamber): –70 °C to +100 °C
Time deviation: ±0.8 K (according to DIN 50011, empty chamber)
Test basket transfer:
Horizontal movement (automated)
Fast changeover for temperature shock tests
Test chamber / usable volume (Type ST2K 1000)
Volume: approx. 580 liters
Internal dimensions: Width approx. 1070 mm, Height approx. 680 mm, Depth approx. 800 mm
Max. load: approx. 150 kg
Power supply:
Total power: max. 33 kVA
Current consumption: max. 65 A
Mains connection: 3 × 400 V / N / PE / 50 Hz
Main power cable: 5 × 25 mm²
Water & compressed air connections
Cooling water inlet: G 1", approx. 3 bar, max. 10 bar / max. 15 °C
Cooling water requirement: max. 3.2 m³/h
Cooling water return: non-pressurized, max. 22 °C
Condensate drains: multiple (non-pressurized)
Compressed air connection: quick-release coupling NW 7.2 (G 1/4"), min. 4 bar, max. 10.5 bar
Dimensions & Weight:
External dimensions:
Width: approx. 2800 mm
Height: approx. 2400 mm
Depth: approx. 2200 mm
Weight: approx. 2800 kg
Equipment
Horizontal basket movement
C-rails in the test chamber
Large test basket (>1000 mm width)
Full-fledged changeover cabinet
Observation window
Internal lighting
SE-604 control unit
Program operation and data recording possible
Hodpfsy H Igfsx Ab Tsfn
RS232 interface
Other technical data
Sound level: approx. 67 dB(A) at 1 m distance (free field)
Refrigerant:
R449A: approx. 8.0 kg (GWP 1397)
R23: approx. 2.5 kg (GWP 14800)
Permissible operating environment:
Temperature: +12 °C to +30 °C
Humidity: 25 %–75 % RH
Operating hours
approx. 4,500 hours
For your security as a buyer, please note the following information!
The following points will be carried out on our offered units in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerants
3. Leak test with certificate
4. Documented test run after successful inspection
Condition: used
Scope of supply: (see pictures)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions by telephone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
RS Simulators ST2K 1000 / 55
Temperature Shock Chamber
Water-cooled
The unit was regularly serviced and maintained by the manufacturer until it was decommissioned.
For sale is a high-performance temperature shock test chamber, type ST2K 1000 / 55.
The unit is ideal for standard-compliant thermal shock tests in accordance with DIN EN 60068-3-5, as well as for demanding material and component tests.
With its two separate temperature chambers and automatic horizontal test basket transfer, this unit offers the perfect solution for reliability tests in industry, automotive, research and quality assurance.
Key technical data:
Temperature ranges
Upper test chamber (hot chamber): +40 °C to +180 °C
Time deviation: ±0.8 K (according to DIN 50011, empty chamber)
Lower test chamber (cold chamber): –70 °C to +100 °C
Time deviation: ±0.8 K (according to DIN 50011, empty chamber)
Test basket transfer:
Horizontal movement (automated)
Fast changeover for temperature shock tests
Test chamber / usable volume (Type ST2K 1000)
Volume: approx. 580 liters
Internal dimensions: Width approx. 1070 mm, Height approx. 680 mm, Depth approx. 800 mm
Max. load: approx. 150 kg
Power supply:
Total power: max. 33 kVA
Current consumption: max. 65 A
Mains connection: 3 × 400 V / N / PE / 50 Hz
Main power cable: 5 × 25 mm²
Water & compressed air connections
Cooling water inlet: G 1", approx. 3 bar, max. 10 bar / max. 15 °C
Cooling water requirement: max. 3.2 m³/h
Cooling water return: non-pressurized, max. 22 °C
Condensate drains: multiple (non-pressurized)
Compressed air connection: quick-release coupling NW 7.2 (G 1/4"), min. 4 bar, max. 10.5 bar
Dimensions & Weight:
External dimensions:
Width: approx. 2800 mm
Height: approx. 2400 mm
Depth: approx. 2200 mm
Weight: approx. 2800 kg
Equipment
Horizontal basket movement
C-rails in the test chamber
Large test basket (>1000 mm width)
Full-fledged changeover cabinet
Observation window
Internal lighting
SE-604 control unit
Program operation and data recording possible
Hodpfsy H Igfsx Ab Tsfn
RS232 interface
Other technical data
Sound level: approx. 67 dB(A) at 1 m distance (free field)
Refrigerant:
R449A: approx. 8.0 kg (GWP 1397)
R23: approx. 2.5 kg (GWP 14800)
Permissible operating environment:
Temperature: +12 °C to +30 °C
Humidity: 25 %–75 % RH
Operating hours
approx. 4,500 hours
For your security as a buyer, please note the following information!
The following points will be carried out on our offered units in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerants
3. Leak test with certificate
4. Documented test run after successful inspection
Condition: used
Scope of supply: (see pictures)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions by telephone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Hantar permintaan
Telefon & Faks
+49 2861 ... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Wien
9,346 km
Kanister bertutup
Verschluss-Kanister
Verschluss-Kanister
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Borken
9,999 km
Memmert CTC 256 Kabinet Ujian Iklim / Kabinet Ujian Suhu -42 hingga +190°C 256 Liter
MemmertCTC 256
MemmertCTC 256
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Jerman
9,760 km
Mesin letupan pasir
HGH6040 Duo
HGH6040 Duo
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Donaueschingen
9,929 km
Ruang semburan garam
Weiss TechnikSC 450
Weiss TechnikSC 450
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Wien
9,346 km
Kosmetik dengan penutup
Verschluss-Kosmetika
Verschluss-Kosmetika
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Schweinfurt
9,785 km
Sistem pengujian getaran Shaker
Data Physics LE-1216-3VH 53,4kNLE-1216-3VH 53,4kN
Data Physics LE-1216-3VH 53,4kNLE-1216-3VH 53,4kN
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Wien
9,346 km
Kosmetik dengan penutup
Verschluss-Kosmetika
Verschluss-Kosmetika
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Borken
9,999 km
Weiss Technik Kabinet Ujian Suhu TempEvent T/1000/70e/5 -70°C hingga +180°C 1000 Liter
WeissTempEvent T/1000/70e/5
WeissTempEvent T/1000/70e/5
Iklan anda telah berjaya dipadamkan
Berlaku ralat