Kalorimeter pengimbasan pembezaanPerkin Elmer
DSC 8000, N5340524
Kalorimeter pengimbasan pembezaan
Perkin Elmer
DSC 8000, N5340524
EXW harga tetap ditambah cukai perkhidmatan
€29,750
Keadaan
Terpakai
Lokasi
Dresden 

Gambar menunjukkan
Tunjukkan peta
Data mesin
- Nama mesin:
- Kalorimeter pengimbasan pembezaan
- Pengeluar:
- Perkin Elmer
- Model:
- DSC 8000, N5340524
- Keadaan:
- terpakai
Harga & Lokasi
EXW harga tetap ditambah cukai perkhidmatan
€29,750
- Lokasi:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

Hubungi
Butiran tawaran
- ID iklan:
- A21283042
- Nombor rujukan:
- LW43630
- Kemas kini:
- terakhir pada 20.02.2026
Penerangan
Perkin Elmer Instruments Differential Scanning Calorimeter with Cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Gjdeyluicjpfx Aggsua
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Gjdeyluicjpfx Aggsua
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Didaftarkan sejak: 2014
97 Iklan dalam talian
Hantar permintaan
Telefon & Faks
+49 351 8... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Iklan kecil
Hannover
9,799 km
Sistem Studio Logam Desktop II
Desktop MetalStudio System II
Desktop MetalStudio System II
Iklan kecil
Borken
9,999 km
10°C hingga +250°C / 749 Liter
Memmert Universal - WärmeschrankUFP 800
Memmert Universal - WärmeschrankUFP 800
Iklan kecil
Borken
9,999 km
Kabinet ujian universal +20 °C hingga +300 °C
MemmertUF 450plus
MemmertUF 450plus
Iklan kecil
Wald
9,879 km
Relau serbaguna Kabinet pemanas
MemmertULP 600
MemmertULP 600
Iklan kecil
Sepanyol
9,967 km
DESKTOP METAL Metal Studio 2
DESKTOP METALMetal Studio 2
DESKTOP METALMetal Studio 2
Iklan anda telah berjaya dipadamkan
Berlaku ralat