Kaunter Zarah Pacific Scientific 3313LL Met OnePacific Scientific
3313LL Met One
Kaunter Zarah Pacific Scientific 3313LL Met One
Pacific Scientific
3313LL Met One
Keadaan
Terpakai
Lokasi
Duxford 

Gambar menunjukkan
Tunjukkan peta
Data mesin
Harga & Lokasi
- Lokasi:
- Duxford, UK

Hubungi
Butiran tawaran
- ID iklan:
- A20502585
- Nombor rujukan:
- 23241.SR11B
- Kemas kini:
- terakhir pada 11.11.2025
Penerangan
This listing is for a Pacific Scientific 3313LL Met One Particle Counter
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Fsdpfxoxv Ab Hs Ahyjft
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Fsdpfxoxv Ab Hs Ahyjft
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Didaftarkan sejak: 2019
Hantar permintaan
Telefon & Faks
+44 20 38... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Iklan kecil
Borken
9,999 km
Haba dan pengeringan Kabinet
HeraeusUT 6060 bis 300 °C
HeraeusUT 6060 bis 300 °C
Iklan kecil
Borken
9,999 km
Kabinet suhu 110 liter
VötschVT 7011 -70°C bis +180°C
VötschVT 7011 -70°C bis +180°C
Iklan kecil
Freising
9,684 km
Mikroskop Elektron Imbasan (Meja)
JEOLJCM-7000
JEOLJCM-7000
Iklan kecil
Borken
9,999 km
Kabinet suhu 110 liter
VötschVT 7011 -70°C bis +180°C
VötschVT 7011 -70°C bis +180°C
Iklan kecil
Piskorzów
9,293 km
Ketuhar termo vakum
ThermoVT 6060 M 200°C
ThermoVT 6060 M 200°C
Iklan kecil
Duxford
10,450 km
Handilaz Mini Particle Counter dengan bekas asal
HandilazMini
HandilazMini
Iklan kecil
Duxford
10,450 km
Kaunter Zarah Mini Handilaz
HandilazMini
HandilazMini
Iklan kecil
Duxford
10,450 km
LASAIR lll 310c Sistem Pengukuran Zarah
Particle Measuring SystemsLASAIR lll 310c
Particle Measuring SystemsLASAIR lll 310c
Iklan kecil
Duxford
10,450 km
Pharmagraph S1816 Pengira Zarah
PharmagraphS1816
PharmagraphS1816
Iklan anda telah berjaya dipadamkan
Berlaku ralat
































































