Oxford Instruments X-Strata 960 penganalisis penjaluran sinar-X (X-ray Fluorescence Analyzer) – untuOxford Instruments
X-Strata 960
Oxford Instruments X-Strata 960 penganalisis penjaluran sinar-X (X-ray Fluorescence Analyzer) – untu
Oxford Instruments
X-Strata 960
Harga tetap ditambah cukai perkhidmatan
€2,500
Keadaan
Terpakai
Lokasi
Borken 

Data asas
- Nama mesin:
- Oxford Instruments X-Strata 960 penganalisis penjaluran sinar-X (X-ray Fluorescence Analyzer) – untu
- Pengeluar:
- Oxford Instruments
- Model:
- X-Strata 960
- Keadaan:
- terpakai
Harga & Lokasi
Harga tetap ditambah cukai perkhidmatan
€2,500
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Butiran tawaran
- ID iklan:
- A22140132
- Nombor rujukan:
- 22086
- Kemas kini:
- terakhir pada 22.10.2026
Penerangan
Oxford Instruments
Oxford Instruments X-Strata 960 X-ray Fluorescence Analyzer – for spare parts / defective
Item Description:
For sale is a used X-ray Fluorescence Analyzer, type Oxford Instruments X-Strata 960.
The unit comes from a laboratory decommissioning and is offered exclusively as a source of spare parts
or for repair purposes.
No functional testing has been performed – therefore, the unit is considered defective for the purposes of this sale.
Technical Data – Oxford Instruments X-Strata 960 (non-binding)
Feature Description
Model X-Strata 960
Manufacturer Oxford Instruments
Analysis Method X-ray Fluorescence Analysis (XRF)
Application Areas Coating thickness measurement, material analysis, precious metal testing
Measurement Geometry Top- or bottom-irradiating, depending on configuration
Radiation Source X-ray tube (e.g., rhodium anode), 50–100 W power
Detector Proportional counter or silicon drift detector (SDD), depending on version
Measurement Range Coating thickness approx. 0.005 – 50 µm (material dependent)
Spot Size approx. 15 μm – 1 mm (depending on collimator)
Z-Axis Motorized, adjustable up to approx. 230 mm measurement height
Sample Chamber (W × D × H) approx. 580 × 510 × 230 mm
Sample Table Manual or motorized (200 × 200 mm or larger, depending on equipment)
Itjdpezdzifsfx Adlop
Focusing System Optical / laser focus, partially automatic
Operating System Integrated industrial PC with Windows-based evaluation software
Voltage Supply 220–240 V / 50–60 Hz / approx. 500–800 W
Unit Weight approx. 150–200 kg (depending on version)
Condition: used / defective / for spare parts
Scope of Delivery: as shown in the images – without accessories or software
Important Notes:
Sold expressly as a defective unit without any warranty of functionality.
The item is offered as a source of spare parts or for hobbyists.
No warranty on function, completeness or technical parameters.
Commercial sale with exclusion of any liability for defects, in accordance with § 447 BGB (distance selling contract).
Scope of Delivery:
Oxford Instruments X-Strata 960
All components visible in the images
Other parts, accessories or documentation are not included, unless explicitly stated.
Shipping & Pickup:
Pickup possible and preferred in Borken
Shipping possible upon agreement.
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Oxford Instruments X-Strata 960 X-ray Fluorescence Analyzer – for spare parts / defective
Item Description:
For sale is a used X-ray Fluorescence Analyzer, type Oxford Instruments X-Strata 960.
The unit comes from a laboratory decommissioning and is offered exclusively as a source of spare parts
or for repair purposes.
No functional testing has been performed – therefore, the unit is considered defective for the purposes of this sale.
Technical Data – Oxford Instruments X-Strata 960 (non-binding)
Feature Description
Model X-Strata 960
Manufacturer Oxford Instruments
Analysis Method X-ray Fluorescence Analysis (XRF)
Application Areas Coating thickness measurement, material analysis, precious metal testing
Measurement Geometry Top- or bottom-irradiating, depending on configuration
Radiation Source X-ray tube (e.g., rhodium anode), 50–100 W power
Detector Proportional counter or silicon drift detector (SDD), depending on version
Measurement Range Coating thickness approx. 0.005 – 50 µm (material dependent)
Spot Size approx. 15 μm – 1 mm (depending on collimator)
Z-Axis Motorized, adjustable up to approx. 230 mm measurement height
Sample Chamber (W × D × H) approx. 580 × 510 × 230 mm
Sample Table Manual or motorized (200 × 200 mm or larger, depending on equipment)
Itjdpezdzifsfx Adlop
Focusing System Optical / laser focus, partially automatic
Operating System Integrated industrial PC with Windows-based evaluation software
Voltage Supply 220–240 V / 50–60 Hz / approx. 500–800 W
Unit Weight approx. 150–200 kg (depending on version)
Condition: used / defective / for spare parts
Scope of Delivery: as shown in the images – without accessories or software
Important Notes:
Sold expressly as a defective unit without any warranty of functionality.
The item is offered as a source of spare parts or for hobbyists.
No warranty on function, completeness or technical parameters.
Commercial sale with exclusion of any liability for defects, in accordance with § 447 BGB (distance selling contract).
Scope of Delivery:
Oxford Instruments X-Strata 960
All components visible in the images
Other parts, accessories or documentation are not included, unless explicitly stated.
Shipping & Pickup:
Pickup possible and preferred in Borken
Shipping possible upon agreement.
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Hantar permintaan
Telefon & Faks
+49 2861 ... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Tata
9,198 km
Tekan hidraulik JAM HYP-1000 10tone
JAM HYP 100010ton
JAM HYP 100010ton
Iklan anda telah berjaya dipadamkan
Berlaku ralat