Kalorimeter Imbasan PembezaanNETZSCH
DSC 200 F3 Maia® + Intracooler 40
Kalorimeter Imbasan Pembezaan
NETZSCH
DSC 200 F3 Maia® + Intracooler 40
harga tetap ditambah cukai perkhidmatan
€11,500
Keadaan
Terpakai
Lokasi
Borken 

Gambar menunjukkan
Tunjukkan peta
Data mesin
Harga & Lokasi
harga tetap ditambah cukai perkhidmatan
€11,500
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Butiran tawaran
- ID iklan:
- A20972012
- Nombor rujukan:
- 24980
- Kemas kini:
- terakhir pada 16.01.2026
Penerangan
Netzsch
Type: DSC 200 F3 Maia® Measuring Device
NETZSCH DSC 200 F3 Maia® with Intracooler 40
Differential Scanning Calorimeter incl. accessories
Description / Scope of Functions
A DSC is used for the thermal analysis of materials. It measures the heat flow that occurs in a sample during physical or chemical processes when it is heated or cooled in a controlled manner. The device enables the investigation of the following material properties, among others:
- Melting and solidification temperatures
- Glass transition temperatures (Tg)
- Crystallization
- Phase transitions
- Reaction enthalpy
- Heat capacity
- Purity determination of substances
Typical fields of application:
Hjdpeyaatpefx Adpjfb
- Materials research & development
- Plastic and polymer analysis
- Metal and alloy analysis
- Chemistry, pharmaceuticals, ceramics
- Quality assurance & laboratory analytics
The Intracooler 40 enables active cooling below room temperature without the need for liquid nitrogen and significantly extends the temperature range.
Scope of delivery (as pictured):
- NETZSCH DSC 200 F3 Maia® measuring device
- NETZSCH Intracooler 40
- Original measuring and handling tools
- Calibration and reference materials (indium, tin, bismuth, zinc, aluminum, silver – approx. 400 mg each)
- Several original packs of DSC crucibles (aluminum, 25 µl)
- Original transport and storage boxes
- Comprehensive NETZSCH original documentation (user manuals, instrument manuals, software manuals)
- NETZSCH Proteus® software incl. data carrier and USB dongle
Technical data (excerpt)
DSC 200 F3 Maia®
Power supply: 230 V / 50 Hz
Power consumption: approx. 500–800 W
Temperature range (with Intracooler 40): approx. -40 °C to +600 °C (depending on configuration)
Measuring principle: Differential Scanning Calorimetry (DSC)
Intracooler 40
Power supply: 230 V / 50 Hz
Current consumption: 2 A
Refrigerant: R507
Protection class: IP21
Max operating pressure: 24 bar
Dimensions & weight (approx.):
DSC 200 F3 Maia®: Dimensions (W × D × H): approx. 60 × 45 × 25 cm; Weight: approx. 35–40 kg
Intracooler 40: Dimensions (W × D × H): approx. 30 × 40 × 50 cm; Weight: approx. 30 kg
Important note:
"The table shown in the photos is not included in the sale."
Condition: used
Scope of delivery: (see picture)
(Specifications and technical details subject to change and errors reserved!)
If you have further questions, we would be happy to answer them by phone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Type: DSC 200 F3 Maia® Measuring Device
NETZSCH DSC 200 F3 Maia® with Intracooler 40
Differential Scanning Calorimeter incl. accessories
Description / Scope of Functions
A DSC is used for the thermal analysis of materials. It measures the heat flow that occurs in a sample during physical or chemical processes when it is heated or cooled in a controlled manner. The device enables the investigation of the following material properties, among others:
- Melting and solidification temperatures
- Glass transition temperatures (Tg)
- Crystallization
- Phase transitions
- Reaction enthalpy
- Heat capacity
- Purity determination of substances
Typical fields of application:
Hjdpeyaatpefx Adpjfb
- Materials research & development
- Plastic and polymer analysis
- Metal and alloy analysis
- Chemistry, pharmaceuticals, ceramics
- Quality assurance & laboratory analytics
The Intracooler 40 enables active cooling below room temperature without the need for liquid nitrogen and significantly extends the temperature range.
Scope of delivery (as pictured):
- NETZSCH DSC 200 F3 Maia® measuring device
- NETZSCH Intracooler 40
- Original measuring and handling tools
- Calibration and reference materials (indium, tin, bismuth, zinc, aluminum, silver – approx. 400 mg each)
- Several original packs of DSC crucibles (aluminum, 25 µl)
- Original transport and storage boxes
- Comprehensive NETZSCH original documentation (user manuals, instrument manuals, software manuals)
- NETZSCH Proteus® software incl. data carrier and USB dongle
Technical data (excerpt)
DSC 200 F3 Maia®
Power supply: 230 V / 50 Hz
Power consumption: approx. 500–800 W
Temperature range (with Intracooler 40): approx. -40 °C to +600 °C (depending on configuration)
Measuring principle: Differential Scanning Calorimetry (DSC)
Intracooler 40
Power supply: 230 V / 50 Hz
Current consumption: 2 A
Refrigerant: R507
Protection class: IP21
Max operating pressure: 24 bar
Dimensions & weight (approx.):
DSC 200 F3 Maia®: Dimensions (W × D × H): approx. 60 × 45 × 25 cm; Weight: approx. 35–40 kg
Intracooler 40: Dimensions (W × D × H): approx. 30 × 40 × 50 cm; Weight: approx. 30 kg
Important note:
"The table shown in the photos is not included in the sale."
Condition: used
Scope of delivery: (see picture)
(Specifications and technical details subject to change and errors reserved!)
If you have further questions, we would be happy to answer them by phone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Hantar permintaan
Telefon & Faks
+49 2861 ... iklan
Iklan anda telah berjaya dipadamkan
Berlaku ralat



























