Penerangan
Memmert ICH 750 chamber from 2022, originally packaged and tested, condition like new, one year warranty on spare parts
Temperature
Set temperature range: -10 to +60 °C
Operating temperature range:
from -10°C to +60°C without humidity
(not suitable for long-term storage at sub-zero temperatures. During continuous operation, glass doors may frost over)
Operating temperature range:
from +10°C to +60°C with humidity and/or light
Temperature setting accuracy: 0.1 °C
Temperature sensors:
2 Pt100 sensors, DIN A class, 4-wire configuration, mutually monitoring and taking over in case of failure
Humidity
Humidity supply:
Distilled water supply from external tank via self-priming pump
Humidification:
Steam generator-based humidification
Humidity:
Active humidification and dehumidification adjustable within the 10–80% rh range with digital relative humidity display – display resolution 0.1%, setpoint accuracy 0.5%
Control Technology
ControlCOCKPIT
TwinDISPLAY. Adaptive, multifunctional digital PID microprocessor controller with two high-resolution TFT color displays.
Adjustable parameters:
temperature (°C or °F), fan speed, relative humidity, program time, time zones, summer/winter time
Language settings:
German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Timer:
Digital countdown timer with target time setting, adjustable from 1 minute to 99 days
SetpointWAIT function:
Process time does not begin until the set temperature is reached
Calibration:
Up to three user-defined values for temperature/humidity and two for CO₂
Ventilation
Fan:
Forced air circulation in the working chamber, adjustable from 10–100% in 10% increments
Communication
Documentation:
Program retained in memory in case of power failure
Programming:
AtmoCONTROL software on USB stick for programming, managing, and transferring programs via Ethernet interface or USB port
Safety
Temperature control:
Mechanical temperature limiter TB, protection class 1 in accordance with DIN 12880, which disconnects heating approx. 10 °C above setpoint temperature
Temperature monitoring:
Over- and under-temperature monitor TWW, safety class 3.3, or adjustable temperature limiter TWB, safety class 2, selectable from display
AutoSAFETY:
Integrated over- and under-temperature protection system "ASF", automatically tracks set value within fixed tolerance range, alarm if temperature is exceeded or falls below threshold; in case of over-temperature, heating is shut off, in under-temperature – compressor
Self-diagnostic system:
Integrated fault diagnosis for temperature and humidity monitoring
Alarm:
Visual and acoustic
Heating concept
Air jacket:
Air jacket heating system for gentle, even heating
Ndodpfoxcgh Rsx Agpof
Heating concept:
No sample drying caused by the cooling unit due to separation of heating jacket from chamber interior
Cooling:
Energy-efficient, CFC-free heating/cooling system, refrigerant R 134A
Defrosting:
High-efficiency, automatic defrost system
Standard equipment
Factory calibration certificate
Standard values: +10°C and +37°C, 60% rh at +30°C
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Temperature
Set temperature range: -10 to +60 °C
Operating temperature range:
from -10°C to +60°C without humidity
(not suitable for long-term storage at sub-zero temperatures. During continuous operation, glass doors may frost over)
Operating temperature range:
from +10°C to +60°C with humidity and/or light
Temperature setting accuracy: 0.1 °C
Temperature sensors:
2 Pt100 sensors, DIN A class, 4-wire configuration, mutually monitoring and taking over in case of failure
Humidity
Humidity supply:
Distilled water supply from external tank via self-priming pump
Humidification:
Steam generator-based humidification
Humidity:
Active humidification and dehumidification adjustable within the 10–80% rh range with digital relative humidity display – display resolution 0.1%, setpoint accuracy 0.5%
Control Technology
ControlCOCKPIT
TwinDISPLAY. Adaptive, multifunctional digital PID microprocessor controller with two high-resolution TFT color displays.
Adjustable parameters:
temperature (°C or °F), fan speed, relative humidity, program time, time zones, summer/winter time
Language settings:
German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Timer:
Digital countdown timer with target time setting, adjustable from 1 minute to 99 days
SetpointWAIT function:
Process time does not begin until the set temperature is reached
Calibration:
Up to three user-defined values for temperature/humidity and two for CO₂
Ventilation
Fan:
Forced air circulation in the working chamber, adjustable from 10–100% in 10% increments
Communication
Documentation:
Program retained in memory in case of power failure
Programming:
AtmoCONTROL software on USB stick for programming, managing, and transferring programs via Ethernet interface or USB port
Safety
Temperature control:
Mechanical temperature limiter TB, protection class 1 in accordance with DIN 12880, which disconnects heating approx. 10 °C above setpoint temperature
Temperature monitoring:
Over- and under-temperature monitor TWW, safety class 3.3, or adjustable temperature limiter TWB, safety class 2, selectable from display
AutoSAFETY:
Integrated over- and under-temperature protection system "ASF", automatically tracks set value within fixed tolerance range, alarm if temperature is exceeded or falls below threshold; in case of over-temperature, heating is shut off, in under-temperature – compressor
Self-diagnostic system:
Integrated fault diagnosis for temperature and humidity monitoring
Alarm:
Visual and acoustic
Heating concept
Air jacket:
Air jacket heating system for gentle, even heating
Ndodpfoxcgh Rsx Agpof
Heating concept:
No sample drying caused by the cooling unit due to separation of heating jacket from chamber interior
Cooling:
Energy-efficient, CFC-free heating/cooling system, refrigerant R 134A
Defrosting:
High-efficiency, automatic defrost system
Standard equipment
Factory calibration certificate
Standard values: +10°C and +37°C, 60% rh at +30°C
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Didaftarkan sejak: 2019
Hantar permintaan
Telefon & Faks
+48 793 1... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Iklan kecil
Menslage
9,921 km
Sefiltra CF4‐S SEF + Penapis Aliran Silang SGG (2021)
sefiltraCrossflow Filter
sefiltraCrossflow Filter
Iklan kecil
Mala Vranjska
9,076 km
Mesin pemprosesan daging
Ital FormSD 95 Vacuum filler
Ital FormSD 95 Vacuum filler
Iklan anda telah berjaya dipadamkan
Berlaku ralat