BILIK Bersih ISO 8
BILIK Bersih ISO 8
EXW VB ditambah cukai perkhidmatan
€50,000
Tahun pembuatan
2020
Keadaan
Terpakai
(berfungsi sepenuhnya)
Lokasi
Łódź 

Data mesin
- Nama mesin:
- BILIK Bersih ISO 8
- Tahun pembuatan:
- 2020
- Keadaan:
- sangat baik (terpakai)
- Fungsi:
- berfungsi sepenuhnya
Harga & Lokasi
EXW VB ditambah cukai perkhidmatan
€50,000
- Lokasi:
- Łódź, Poland

Hubungi
Butiran tawaran
- ID iklan:
- A14477200
- Kemas kini:
- terakhir pada 02.01.2024
Penerangan
CLEANROOM - ISO 8
| Cleanroom requirements ISO Class 8 | ISO Cleanroom Class 8 | Cleanroom classification.
In order to achieve an ISO 8 air purity class in a Cleanroom, several levels of air filtration are usually used (e.g. G4 pre-filter, F9 filter, H13 final filter). Air movement in the room is non-unidirectional (there is a mixing of "clean" air supplied to the room with "dirty" air present in the room). Air vents in the ISO 8 room are placed on the walls. The required number of air exchanges per hour will depend on the nature of the activities conducted in the room and the number of personnel present, but the goal could be to provide 10-40 air exchanges/hr. In ISO Class 8, personnel are often present continuously. Employees may be dressed in standard work attire and visitors in a disposable apron. It is recommended to maintain a minimum overpressure of the room relative to the adjacent zone of 5-10 Pa.
Requirements for equipment and materials intended for Clean Room with ISO air cleanliness class 8 (maximum average amount of particles released when: number of samples taken = 100; measurement performed in accordance with ISO 14644-14 in a cleanliness class at least one better than the purpose of the device; number of particles/m3) Detailed description in photos.
Technical drawings attached to photos.
Kdjdpfx Aeq H H Rujl Aon
Description of ventilation
The purpose of the ventilation installation performed was to achieve the following air parameters in the Clean Room. The installation was made with the GBD PHARMA 2000 system, meeting all the requirements for 'clean rooms' in the highest classes of air purity.
Parameters for the installation: a. Air purity - ISO 8. b. Temperature 19-23 st C
c. Humidity max 38%.
a. To ensure the required purity of the supplied air, an air handling unit manufactured by DOSPEL with a maximum capacity of V= 3500 m3/h [up to 15 air changes per hour] was used. The air handling unit is equipped with pocket filters : pre-filters FK EU5/EC2 and fine filters FK-EU9/EC2. In addition, HEPA 11 filters made by EUFILTER were used in diffusers located in the ceiling. Data sheets in point H6.
As a result , with a measured flow rate of 3264 m3/h, an ISO 7 [class "C"] cleanliness class of the room was obtained in the resting state, and thus an ISO 8 [class "D" ] cleanliness class for the working state.
b. The temperature range of 19-23 deg C is for the enlarged cooler and chiller to be freely maintained with 25% fresh air.
c. In order to achieve in summer conditions with high temperatures of 30 deg C and humidity of 80%, a freon chiller of 31.4 kW and a chiller of 33.5 kW of cooling power were used. The chiller is made by FUJITSU supplied by Klimatherm Gdansk.
The room is automatically regulated overpressure in relation to the external pressure - the pressure difference at the door : 15 Pa
The automation of ventilation allows for "economical" mode , in which the installation works in a closed circuit and an overpressure of 15 Pa is maintained.
Technical data attached to the photos.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
| Cleanroom requirements ISO Class 8 | ISO Cleanroom Class 8 | Cleanroom classification.
In order to achieve an ISO 8 air purity class in a Cleanroom, several levels of air filtration are usually used (e.g. G4 pre-filter, F9 filter, H13 final filter). Air movement in the room is non-unidirectional (there is a mixing of "clean" air supplied to the room with "dirty" air present in the room). Air vents in the ISO 8 room are placed on the walls. The required number of air exchanges per hour will depend on the nature of the activities conducted in the room and the number of personnel present, but the goal could be to provide 10-40 air exchanges/hr. In ISO Class 8, personnel are often present continuously. Employees may be dressed in standard work attire and visitors in a disposable apron. It is recommended to maintain a minimum overpressure of the room relative to the adjacent zone of 5-10 Pa.
Requirements for equipment and materials intended for Clean Room with ISO air cleanliness class 8 (maximum average amount of particles released when: number of samples taken = 100; measurement performed in accordance with ISO 14644-14 in a cleanliness class at least one better than the purpose of the device; number of particles/m3) Detailed description in photos.
Technical drawings attached to photos.
Kdjdpfx Aeq H H Rujl Aon
Description of ventilation
The purpose of the ventilation installation performed was to achieve the following air parameters in the Clean Room. The installation was made with the GBD PHARMA 2000 system, meeting all the requirements for 'clean rooms' in the highest classes of air purity.
Parameters for the installation: a. Air purity - ISO 8. b. Temperature 19-23 st C
c. Humidity max 38%.
a. To ensure the required purity of the supplied air, an air handling unit manufactured by DOSPEL with a maximum capacity of V= 3500 m3/h [up to 15 air changes per hour] was used. The air handling unit is equipped with pocket filters : pre-filters FK EU5/EC2 and fine filters FK-EU9/EC2. In addition, HEPA 11 filters made by EUFILTER were used in diffusers located in the ceiling. Data sheets in point H6.
As a result , with a measured flow rate of 3264 m3/h, an ISO 7 [class "C"] cleanliness class of the room was obtained in the resting state, and thus an ISO 8 [class "D" ] cleanliness class for the working state.
b. The temperature range of 19-23 deg C is for the enlarged cooler and chiller to be freely maintained with 25% fresh air.
c. In order to achieve in summer conditions with high temperatures of 30 deg C and humidity of 80%, a freon chiller of 31.4 kW and a chiller of 33.5 kW of cooling power were used. The chiller is made by FUJITSU supplied by Klimatherm Gdansk.
The room is automatically regulated overpressure in relation to the external pressure - the pressure difference at the door : 15 Pa
The automation of ventilation allows for "economical" mode , in which the installation works in a closed circuit and an overpressure of 15 Pa is maintained.
Technical data attached to the photos.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Didaftarkan sejak: 2023
1 Iklan dalam talian
Hantar permintaan
Telefon & Faks
+48 728 4... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Nordrhein-Westfalen
9,980 km
Mesin gergaji logam & gergaji logam elektrik
BEHRINGERHBE 320-523
BEHRINGERHBE 320-523
Iklan kecil
Bremen
9,856 km
Lif penyimpanan
Kardex RemstarShuttle XP 500 4050x813
Kardex RemstarShuttle XP 500 4050x813
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Nordrhein-Westfalen
9,973 km
Pusat pemesinan menegak
Deckel MahoDMU 50 M
Deckel MahoDMU 50 M
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Jerman
9,973 km
Pelarik turet menegak
YU SHINEVL 1200 ATC
YU SHINEVL 1200 ATC
Iklan kecil
Zuchwil
10,008 km
Mesin pengimbang
HaimerTD 2009
HaimerTD 2009
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Nordrhein-Westfalen
10,037 km
Lengan sendi pengukur 3D
ZETT MESSAMPG Gauge 1200
ZETT MESSAMPG Gauge 1200
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Nordrhein-Westfalen
10,037 km
Lengan sendi pengukur 3D
ZETT MESSAMPG Präzision 3000
ZETT MESSAMPG Präzision 3000
Iklan kecil
Ahaus
9,987 km
Kren tiang tiang
ABUSLS / 4000 MM x 1000 KG
ABUSLS / 4000 MM x 1000 KG
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Hessen
9,875 km
Sistem kontena pejabat
KleusbergOffice Container Facility
KleusbergOffice Container Facility
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Województwo wielkopolskie
9,360 km
Pusat pemesinan
WeekeOptimat BHC 750 Swiss Profiline
WeekeOptimat BHC 750 Swiss Profiline
Iklan kecil
Meiningen
9,765 km
Ketuhar udara edaran 300°C elektrik
Ingenieurbüro Klein mit Umluft, NanodacUK 8820-300
Ingenieurbüro Klein mit Umluft, NanodacUK 8820-300
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Zürich
9,925 km
Mesin lipat plat logam
SalvagniniP4-1812.MLA
SalvagniniP4-1812.MLA
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Sachsen
9,625 km
Pelarik CNC
EMCOTurn 325
EMCOTurn 325
Iklan kecil
Enschede
9,994 km
Mesin pemotong laser tiub
Bodor K2
Bodor K2
Lelong
Tamat dalam
d
h
min
s
Lelong telah tamat
Sachsen
9,625 km
Mesin pelarik menegak
GILDEMEISTERCTV 250
GILDEMEISTERCTV 250
Iklan anda telah berjaya dipadamkan
Berlaku ralat








































































































































































































