Penganalisis Gas Hitech Instruments GIR250Hitech Instruments
GIR250
Penganalisis Gas Hitech Instruments GIR250
Hitech Instruments
GIR250
Keadaan
Terpakai
Lokasi
Duxford 

Gambar menunjukkan
Tunjukkan peta
Data mesin
- Nama mesin:
- Penganalisis Gas Hitech Instruments GIR250
- Pengeluar:
- Hitech Instruments
- Model:
- GIR250
- Keadaan:
- terpakai
Harga & Lokasi
- Lokasi:
- Duxford, UK

Hubungi
Butiran tawaran
- ID iklan:
- A20123055
- Nombor rujukan:
- 240850/7B
- Kemas kini:
- terakhir pada 02.10.2025
Penerangan
This listing is for the Hitech Instruments GIR250 Gas Analyser
The unit is in full working condition and is ready for immediate use
The GIR250 is a bench‑top / transportable analyser designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously in gas samples.
It is made by Hitech Instruments (now part of the MTL / Eaton group).
Its design emphasizes ease of use, reliability, and low maintenance cost.
Other supporting features:
The instrument can be programmed with pass/fail criteria for each gas (alarms).
It provides analog outputs, typically 4–20 mA, for external logging or control systems.
Calibration is designed to be simple (via the front panel keypad) to reduce training burden.
The Oâ‚‚ galvanic cell is user-replaceable (i.e. maintenance can be performed in the field).
Mechanical, Electrical & Operational Details
The GIR250 is housed in a rugged, transportable case (lab-style) so it can be used as a benchtop or mobile analyser.
Sample inlet and outlet connections use 0.25″ (~6 mm) tubing.
The sample system should avoid condensation and contaminants; non‑condensing sample environment is required.
Operating ambient temperature: –5 to +40 °C (for non‑condensing conditions)
Power / interface: standard for bench‑top analysers (the catalogue doesn’t always detail it, but likely mains or DC supply, suitable for lab use)
Typical Applications & Suitability
Because it can measure both Oâ‚‚ and COâ‚‚ in a single unit, the GIR250 is used in applications such as:
Dwjdpfxjxhdqte Ad Djf
Respiration / breathing gas analysis / Douglas bag analysis (i.e. in physiological or experimental gas mixture measurement)
Fermentation / bioprocess monitoring (where Oâ‚‚ and COâ‚‚ both matter)
Gas mixture / inertisation / process gas quality (checking gas purity, calibrating mixtures)
It is not primarily intended for measuring very low trace levels (ppm-level) of Oâ‚‚ or COâ‚‚ unless its ranges are suitably adapted or specified. The design is more for percent-range analysis
The unit is in full working condition and is ready for immediate use
The GIR250 is a bench‑top / transportable analyser designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously in gas samples.
It is made by Hitech Instruments (now part of the MTL / Eaton group).
Its design emphasizes ease of use, reliability, and low maintenance cost.
Other supporting features:
The instrument can be programmed with pass/fail criteria for each gas (alarms).
It provides analog outputs, typically 4–20 mA, for external logging or control systems.
Calibration is designed to be simple (via the front panel keypad) to reduce training burden.
The Oâ‚‚ galvanic cell is user-replaceable (i.e. maintenance can be performed in the field).
Mechanical, Electrical & Operational Details
The GIR250 is housed in a rugged, transportable case (lab-style) so it can be used as a benchtop or mobile analyser.
Sample inlet and outlet connections use 0.25″ (~6 mm) tubing.
The sample system should avoid condensation and contaminants; non‑condensing sample environment is required.
Operating ambient temperature: –5 to +40 °C (for non‑condensing conditions)
Power / interface: standard for bench‑top analysers (the catalogue doesn’t always detail it, but likely mains or DC supply, suitable for lab use)
Typical Applications & Suitability
Because it can measure both Oâ‚‚ and COâ‚‚ in a single unit, the GIR250 is used in applications such as:
Dwjdpfxjxhdqte Ad Djf
Respiration / breathing gas analysis / Douglas bag analysis (i.e. in physiological or experimental gas mixture measurement)
Fermentation / bioprocess monitoring (where Oâ‚‚ and COâ‚‚ both matter)
Gas mixture / inertisation / process gas quality (checking gas purity, calibrating mixtures)
It is not primarily intended for measuring very low trace levels (ppm-level) of Oâ‚‚ or COâ‚‚ unless its ranges are suitably adapted or specified. The design is more for percent-range analysis
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Didaftarkan sejak: 2019
Hantar permintaan
Telefon & Faks
+44 20 38... iklan
Iklan anda telah berjaya dipadamkan
Berlaku ralat












