Tab mandi air kacau Grant GD120Grant GD120 Stirred Water Bath
Grant GD120 Stirred Water Bath
Tab mandi air kacau Grant GD120
Grant GD120 Stirred Water Bath
Grant GD120 Stirred Water Bath
Keadaan
Terpakai
Lokasi
Duxford 

Data mesin
- Nama mesin:
- Tab mandi air kacau Grant GD120
- Pengeluar:
- Grant GD120 Stirred Water Bath
- Keadaan:
- terpakai
Harga & Lokasi
- Lokasi:
- Duxford, UK

Hubungi
Butiran tawaran
- ID iklan:
- A20123960
- Nombor rujukan:
- 40841.SR13C
- Kemas kini:
- terakhir pada 02.10.2025
Penerangan
This listing is for the Grant GD120 Water Bath/Circulator
The unit is in full working condition and is ready for immediate use
The Grant GD120 is a digitally controlled stirred water bath and circulator ideal for laboratory use, offering high precision and flexibility. Here's a breakdown of its features and capabilities:
Key Features
Immersion Thermostat with Intelligent Control Optimisation (ICO): Enables adaptive PID control for exceptionally stable temperature regulation.
Integral Pump: Built-in circulation pump with a maximum flow rate of 17 L/min, allowing both sample immersion and external fluid circulation.
User Interface: Equipped with a clear digital display, a rotor plus two-key control, timer function for reaction timing, and visual + audible alarms to notify operators of critical conditions.
Preset Temperature Control: Supports one adjustable operating setpoint plus three preset temperature options for fast switching.
Safety Features: Includes float-switch low liquid protection and an adjustable over-temperature cut-out for sample and user safety.
Liquid Type Selection: Automatically adjusts heater power and temperature parameters depending on chosen liquid (e.g., water, oil, glycol mixtures).
Temperature Range & Accuracy
Plastic Tanks (P-series): From around ambient +5 °C up to ~99 °C.
Hodpfx Aoxhfl Esl Nonn
Stainless Steel Tanks (S-series): From –15 °C up to ~120 °C.
High Stability: ±0.02 °C for stable temperature control.
Technical Specifications & Obsolescence
The GD120 series includes multiple tank sizes: plastic tanks (P5, P12, P18) and stainless steel tanks (S5, S12, S18, S26, S38), offering varied capacities for different lab needs.
This series is now considered obsolete, though it remains functional and reliable for many applications.
Supporting Documentation & Manual
Operating Manual: The GD120 is covered by the general purpose stirred thermostatic baths manual (shared with GD100), outlining temperature settings, calibration procedures, safety guidance, and maintenance.
Datasheet Summary: Positioned within the broader Grant Optima product range, the GD120 sits between simpler (GD100, up to 100 °C) and higher-spec models (GR150 up to 150 °C, GP200 up to 200 °C)
The unit is in full working condition and is ready for immediate use
The Grant GD120 is a digitally controlled stirred water bath and circulator ideal for laboratory use, offering high precision and flexibility. Here's a breakdown of its features and capabilities:
Key Features
Immersion Thermostat with Intelligent Control Optimisation (ICO): Enables adaptive PID control for exceptionally stable temperature regulation.
Integral Pump: Built-in circulation pump with a maximum flow rate of 17 L/min, allowing both sample immersion and external fluid circulation.
User Interface: Equipped with a clear digital display, a rotor plus two-key control, timer function for reaction timing, and visual + audible alarms to notify operators of critical conditions.
Preset Temperature Control: Supports one adjustable operating setpoint plus three preset temperature options for fast switching.
Safety Features: Includes float-switch low liquid protection and an adjustable over-temperature cut-out for sample and user safety.
Liquid Type Selection: Automatically adjusts heater power and temperature parameters depending on chosen liquid (e.g., water, oil, glycol mixtures).
Temperature Range & Accuracy
Plastic Tanks (P-series): From around ambient +5 °C up to ~99 °C.
Hodpfx Aoxhfl Esl Nonn
Stainless Steel Tanks (S-series): From –15 °C up to ~120 °C.
High Stability: ±0.02 °C for stable temperature control.
Technical Specifications & Obsolescence
The GD120 series includes multiple tank sizes: plastic tanks (P5, P12, P18) and stainless steel tanks (S5, S12, S18, S26, S38), offering varied capacities for different lab needs.
This series is now considered obsolete, though it remains functional and reliable for many applications.
Supporting Documentation & Manual
Operating Manual: The GD120 is covered by the general purpose stirred thermostatic baths manual (shared with GD100), outlining temperature settings, calibration procedures, safety guidance, and maintenance.
Datasheet Summary: Positioned within the broader Grant Optima product range, the GD120 sits between simpler (GD100, up to 100 °C) and higher-spec models (GR150 up to 150 °C, GP200 up to 200 °C)
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Didaftarkan sejak: 2019
804 Iklan dalam talian
Hantar permintaan
Telefon & Faks
+44 20 38... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Iklan kecil
Hessisch Lichtenau
9,810 km
Mikro imbangan, penimbang makmal, penimbang ketepatan, penimbang halus, penimbang, mikro imbangan, m
METTLER TOLEDOXS3DU
METTLER TOLEDOXS3DU
Iklan kecil
Duxford
10,450 km
Penimbang Sartorius MSA124S
SartoriusMSA124S
SartoriusMSA124S
Iklan kecil
Olsztyn
9,082 km
Spektrometer ICP MS NEXION 2000
Perkin ElmerNEXION 2000
Perkin ElmerNEXION 2000
Iklan kecil
London
10,481 km
Sartorius MSA225S-1CE-D1 Timbangan Solent + Pencetak Cubis MCA623S
SartoriusMSE1245
SartoriusMSE1245
Iklan kecil
Duxford
10,450 km
Sartorius Timbang Tare CP4202S + Pencetak YDP20-OCE
SartoriusTare CP4202S
SartoriusTare CP4202S
Iklan kecil
Duxford
10,450 km
Kabinet Keselamatan Semper Safehood 120
SemperSafehood 120
SemperSafehood 120
Iklan kecil
Duxford
10,450 km
Thermo Scientific Precision CIR19 Mandian Beredar Berhaba
Thermo Fisher ScientificPrecision CIR19
Thermo Fisher ScientificPrecision CIR19
Iklan kecil
Wald
9,879 km
Peranti Pengukur pH, Fluorida & Konduktiviti
WTWMulti 9630 IDS | SenTix | TetraCon
WTWMulti 9630 IDS | SenTix | TetraCon
Iklan kecil
Duxford
10,450 km
Sistem Penulenan Air Millipore Elix Essential 10 UV
MilliporeElix Essential 10 UV
MilliporeElix Essential 10 UV
Iklan kecil
London
10,481 km
Sartorius MSA225S-1CE-D1 + Pencetak Sartorius YDP10
SartoriusMSE1245
SartoriusMSE1245
Iklan anda telah berjaya dipadamkan
Berlaku ralat