GBS Prüfpuls rev3 penjana denyut untuk ujian pengasingan jangka panjang sehingga 6nFGBS Elektronik
rev3 Isolationstests bis 6nF
GBS Prüfpuls rev3 penjana denyut untuk ujian pengasingan jangka panjang sehingga 6nF
GBS Elektronik
rev3 Isolationstests bis 6nF
VB ditambah cukai perkhidmatan
€3,781
Keadaan
Terpakai
Lokasi
Borken 

Data asas
Harga & Lokasi
VB ditambah cukai perkhidmatan
€3,781
- Lokasi:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Hubungi
Butiran tawaran
- ID iklan:
- A17569468
- Nombor rujukan:
- 21007
- Kemas kini:
- terakhir pada 13.11.2026
Penerangan
GBS Prüfpuls rev3 Pulse generator for long-term insulation tests
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
Gujdpfju Egz Rex Ahboi
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
More items - new and used - can be found in our shop!
International shipping costs on request!
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
The Prüfpuls unit is designed for long-term insulation tests on test specimens with a capacity of up to 6 nF.
Converter for high-voltage test transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation 16-24 kHz of the sine wave via a full bridge.
· Converter voltage adjustable from 0-600 V, Imax = 2.6 A, maximum power 1.3 kW
· Pulse current limitation 110 A (shutdown threshold)
Pulse transformer – drive
· Drive via a full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limitation 100 A (shutdown threshold).
· Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances 150 μH, 300 μH, to adjust the pulse width or rise times to the load capacity and voltage.
Gujdpfju Egz Rex Ahboi
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating, depending on the polarity of the sine wave signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-stage cascaded circuit.
· Total turns ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
· Maximum output voltage 15 kV with possible load capacities of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· Voltage divider 1:1000 in parallel.
· Overvoltage protection at approx. 20-23 kV by parallel spark gaps
· Thermistor for over-temperature detection in the 1st transformer stage.
· Earth-side current measurement socket 100 mV/A.
Breakdown detection, testing
· If the maximum bridge currents for the transformer drive or the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hour counter to determine the test time.
Manufacturer's price approx. €59,500
More items - new and used - can be found in our shop!
International shipping costs on request!
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Kali terakhir dalam talian: minggu lepas
Didaftarkan sejak: 2008
530 Iklan dalam talian
Hantar permintaan
Telefon & Faks
+49 2862 ... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Wiefelstede
9,900 km
Naib bangku 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Iklan anda telah berjaya dipadamkan
Berlaku ralat