Fresenius Pilot A2 Syringe Pump
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In everyday medical practice, the device is used for the continuous, precisely controlled administration of highly potent medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear operating panel, a digital display for rate indication, and automatic safety and alarm functions.
Thanks to the already mounted, robust original bracket on the back, the pump can be securely attached to infusion stands, intensive care beds, or standardized medical rails in no time.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (presets for BD Plastipak, Braun Perfusor, and Monoject, among others, can be read directly on the housing).
- Clear operating panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for exact rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery.
- Mobility: Integrated battery for bridging during patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Delivery rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1 % (drive mechanism), ± 2 % (syringe)
Power supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Pgodpj Af Uynofx Al Ueu
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety features: Audible and visual alarm systems (e.g., in case of occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2012
"Everything from one source: We would be happy to offer you suitable bank financing for your project."
You can find more new and used items in our shop!
International shipping costs on request!
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
In everyday medical practice, the device is used for the continuous, precisely controlled administration of highly potent medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear operating panel, a digital display for rate indication, and automatic safety and alarm functions.
Thanks to the already mounted, robust original bracket on the back, the pump can be securely attached to infusion stands, intensive care beds, or standardized medical rails in no time.
Features:
- High flexibility: Automatic detection and compatibility with common 20 ml and 50 ml Luer-Lock syringes (presets for BD Plastipak, Braun Perfusor, and Monoject, among others, can be read directly on the housing).
- Clear operating panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for exact rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery.
- Mobility: Integrated battery for bridging during patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Delivery rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1 % (drive mechanism), ± 2 % (syringe)
Power supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Pgodpj Af Uynofx Al Ueu
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety features: Audible and visual alarm systems (e.g., in case of occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2012
"Everything from one source: We would be happy to offer you suitable bank financing for your project."
You can find more new and used items in our shop!
International shipping costs on request!
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Kali terakhir dalam talian: minggu lepas
Didaftarkan sejak: 2008
536 Iklan dalam talian
Hantar permintaan
Telefon & Faks
+49 2862 ... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Borken
10,005 km
Fresenius Vial Pilot A2 Pam Infusi Picagari Perubatan Perfusor
FreseniusPilot A2
FreseniusPilot A2
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Borken
10,005 km
Pam Infusi Picagari Perubatan Fresenius Vial Pilot A2 (Perfusor)
FreseniusPilot A2
FreseniusPilot A2
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Borken
10,005 km
Pam picagari infusi perubatan Fresenius Vial Pilot A2
FreseniusPilot A2
FreseniusPilot A2
Iklan anda telah berjaya dipadamkan
Berlaku ralat