SN 162699
Closing force (kN) 600 (expandable to 800 kN)
Year of manufacture: 2003
Screw diameter 30.00 mm, L/D ratio of the mixing cylinder 20.50
Operating hours: ONLY 6,500
Vertically enlarged clamping plates (B-plates)
Swiveling reject chute for reject selection, activated upon reject detection
Version variant HV 2 with control pumps (pressure and flow control in a closed-loop control system)
for parallel movement sequence
Microcomputer CC100 A03
Kistler 5155 A2213Q02 charge amplifier with automatic switching pressure detection
4x digital output, 4x digital input
Interface for temperature control units or hot runner controllers
Data protocol Engel, physical type 20 mA – CL
Microflow
MINI-CAM - Process parameter adjustment support based on an expert system
Dodozcanfopfx Ag Iouu
1x service socket, 2-pole, 230V
4x 3-phase socket, 10A / 16A
2x 3-phase socket, 10A / 16A, switchable
2/2-way solenoid air valve, R1/4 inch
Flow regulator 0-10 l, 8 circuits
Temperature control circuits can be switched off manually or automatically (centrally at the flow controller) – Switch-off function selectable.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
SN 162699
Closing force (kN) 600 (expandable to 800 kN)
Year of manufacture: 2003
Screw diameter 30.00 mm, L/D ratio of the mixing cylinder 20.50
Operating hours: ONLY 6,500
Vertically enlarged clamping plates (B-plates)
Swiveling reject chute for reject selection, activated upon reject detection
Version variant HV 2 with control pumps (pressure and flow control in a closed-loop control system)
for parallel movement sequence
Microcomputer CC100 A03
Kistler 5155 A2213Q02 charge amplifier with automatic switching pressure detection
4x digital output, 4x digital input
Interface for temperature control units or hot runner controllers
Data protocol Engel, physical type 20 mA – CL
Microflow
MINI-CAM - Process parameter adjustment support based on an expert system
Dodozcanfopfx Ag Iouu
1x service socket, 2-pole, 230V
4x 3-phase socket, 10A / 16A
2x 3-phase socket, 10A / 16A, switchable
2/2-way solenoid air valve, R1/4 inch
Flow regulator 0-10 l, 8 circuits
Temperature control circuits can be switched off manually or automatically (centrally at the flow controller) – Switch-off function selectable.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Kali terakhir dalam talian: Semalam
Didaftarkan sejak: 2021
10 Iklan dalam talian
Hantar permintaan
Telefon & Faks
+386 31 7... iklan
Iklan anda telah berjaya dipadamkan
Berlaku ralat