Kamar Suhu CTS CTS T-40/2000 Suhu -40°C hingga +180°C 2000 LiterCTS
T-40/2000
Kamar Suhu CTS CTS T-40/2000 Suhu -40°C hingga +180°C 2000 Liter
CTS
T-40/2000
Keadaan
Terpakai
Lokasi
Borken 

Harga & Lokasi
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Butiran tawaran
- ID iklan:
- A22215232
- Nombor rujukan:
- 24329
- Kemas kini:
- terakhir pada 15.10.2026
Penerangan
CTS
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, hermetically sealed, stepless power adjustment
via electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, left-hand door stop,
one-hand operation, lockable.
Insert shelf:
stainless steel, support area 970 x 980 + 500 mm
load per shelf max. 35 kg
total load with max. shelf load 100 kg
Test chamber lighting: 3x halogen lamp 20 W, 12 V
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input of setpoints
Plain text error messages
RS 232 interface
free switching channels for on-site control of the test item
Temperature range: -40°C to +180°C
Rated voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Rated current: 17.2 A
Compressor: TFH2516Z
Pipe connection NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test item, without radiation and without additional devices.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: height 900, width 975, depth 2200 mm
External dimensions: height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Hjdpfx Alszg Twajtefn
Condensate drain, non-pressurized, R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1m from the front) < 55 dB(A)
Weight: approx. 1200 kg
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, hermetically sealed, stepless power adjustment
via electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, left-hand door stop,
one-hand operation, lockable.
Insert shelf:
stainless steel, support area 970 x 980 + 500 mm
load per shelf max. 35 kg
total load with max. shelf load 100 kg
Test chamber lighting: 3x halogen lamp 20 W, 12 V
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input of setpoints
Plain text error messages
RS 232 interface
free switching channels for on-site control of the test item
Temperature range: -40°C to +180°C
Rated voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Rated current: 17.2 A
Compressor: TFH2516Z
Pipe connection NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test item, without radiation and without additional devices.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: height 900, width 975, depth 2200 mm
External dimensions: height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Hjdpfx Alszg Twajtefn
Condensate drain, non-pressurized, R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1m from the front) < 55 dB(A)
Weight: approx. 1200 kg
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Hantar permintaan
Telefon & Faks
+49 2861 ... iklan
Iklan-iklan ini juga mungkin menarik minat anda.
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Borken
9,999 km
Weiss bilik ujian iklim dengan kelembapan -42°C hingga +180°C, kira-kira 335 liter, model WK3-340/40
WeissKlimaprüfschrank
WeissKlimaprüfschrank
Berjaya
Mesej anda telah dihantar.
Iklan kecil
Borken
9,999 km
Vötsch Kabinet Ujian Iklim VC 4034 Julat Suhu -40°C hingga +180°C 335 Liter
VötschVC 4034
VötschVC 4034
Iklan anda telah berjaya dipadamkan
Berlaku ralat