Pengawal aliran jisim MFC digital baharu untuk gas, SLA5800 Biotech MassFlowControllerBROOKS INSTRUMENT
SLA585081BAB1A2S1
Pengawal aliran jisim MFC digital baharu untuk gas, SLA5800 Biotech MassFlowController
BROOKS INSTRUMENT
SLA585081BAB1A2S1
harga tetap ditambah cukai perkhidmatan
€1,000
Keadaan
Terpakai
Lokasi
Hessisch Lichtenau 

Gambar menunjukkan
Tunjukkan peta
Data mesin
Harga & Lokasi
harga tetap ditambah cukai perkhidmatan
€1,000
- Lokasi:
- 37235 Hessisch Lichtenau

Hubungi
Butiran tawaran
- ID iklan:
- A17208372
- Nombor rujukan:
- 61764
- Kemas kini:
- terakhir pada 14.09.2025
Penerangan
SLA5800 Biotech - MFC - Digitally controlled mass flow controller for gas, Mass Flow Controller
elastomer-sealed mass flow controller, flow control, flow meter, flow controller, thermal mass flow
BROOKS INSTRUMENT Type SLA585081BAB1A2S1
Ser. No. 01C00500222
Year of manufacture 2020 (new / unused in original packaging)
SLA5800 Biotech series
Option package Biotech Premium Packet Code T
Mains connection 13.5 - 27 VDC (plug M8, 5 pin, male)
Power consumption max. 10 watts
PROFINET interface (2x RJ-45)
Visual display 2 LEDs (NET / MOD)
Gas connection 6 mm Swagelok
Cjdjuqgbyspfx Ad Djrk
Valve design Normally closed
User gas O2 (oxygen) Active - Multiple / O2 (oxygen), N2 (nitrogen), CO2 (carbon dioxide), AIR (air)
Calibration gas N2 (nitrogen)
Flow control ranges (full scale) 20000 sccm (20 liters / minute)
Maximum inlet pressure 4500 psi (300 bar)
Normal operation Pressure differential 60 psig (4 bar)
Control range 2% to 100% of full scale (range of mechanism)
Typical accuracy from 20 to 100 % ± 0.9 % of set point for 20 to 100 % of full scale
Typical accuracy from 2 to 20 % ± 0.18 % of full scale for 2 to 20 % of full scale
Repeatability ± 0.2 % of the measured value
Resolution 0.1 % of full scale
Typical response time of the controller
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
elastomer-sealed mass flow controller, flow control, flow meter, flow controller, thermal mass flow
BROOKS INSTRUMENT Type SLA585081BAB1A2S1
Ser. No. 01C00500222
Year of manufacture 2020 (new / unused in original packaging)
SLA5800 Biotech series
Option package Biotech Premium Packet Code T
Mains connection 13.5 - 27 VDC (plug M8, 5 pin, male)
Power consumption max. 10 watts
PROFINET interface (2x RJ-45)
Visual display 2 LEDs (NET / MOD)
Gas connection 6 mm Swagelok
Cjdjuqgbyspfx Ad Djrk
Valve design Normally closed
User gas O2 (oxygen) Active - Multiple / O2 (oxygen), N2 (nitrogen), CO2 (carbon dioxide), AIR (air)
Calibration gas N2 (nitrogen)
Flow control ranges (full scale) 20000 sccm (20 liters / minute)
Maximum inlet pressure 4500 psi (300 bar)
Normal operation Pressure differential 60 psig (4 bar)
Control range 2% to 100% of full scale (range of mechanism)
Typical accuracy from 20 to 100 % ± 0.9 % of set point for 20 to 100 % of full scale
Typical accuracy from 2 to 20 % ± 0.18 % of full scale for 2 to 20 % of full scale
Repeatability ± 0.2 % of the measured value
Resolution 0.1 % of full scale
Typical response time of the controller
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Hantar permintaan
Telefon & Faks
+49 5602 ... iklan
Iklan anda telah berjaya dipadamkan
Berlaku ralat





















