Peranti kawalan suhu 6 litarAutotherm
AWF 130-27/VK/6K
Peranti kawalan suhu 6 litar
Autotherm
AWF 130-27/VK/6K
harga tetap ditambah cukai perkhidmatan
€80,000
Keadaan
Terpakai
Lokasi
Borken 

Gambar menunjukkan
Tunjukkan peta
Data mesin
- Nama mesin:
- Peranti kawalan suhu 6 litar
- Pengeluar:
- Autotherm
- Model:
- AWF 130-27/VK/6K
- Keadaan:
- sangat baik (terpakai)
Harga & Lokasi
harga tetap ditambah cukai perkhidmatan
€80,000
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Butiran tawaran
- ID iklan:
- A8776937
- Nombor rujukan:
- 23415
- Kemas kini:
- terakhir pada 15.11.2024
Penerangan
Autotherm
Here we offer you a 6-circuit temperature control device.
Without active refrigerating machine!
According to the enclosed technical brief description:
Temperature range: -40°C ... +85°C (extended temperature range -40°C...+130°C)
increased heating power 27 kW instead of 18 kW
with 1x temperature control included in the main line
with 6x temperature measurement in the respective flow included
with 6x temperature measurement in the respective return included
with 6x volume flow and pressure measurement in the respective flow included
with 6x volume flow and pressure control included
1l/min ... 12 l/min and 0.1 bar ... 3 bar
incl. release control
incl. FU-controlled pump in the main line
incl. 6x 3-way valve
with 6x additional overflow valve 2 ... 12 bar adjustable included
preset to 2,4 bar
with filling and draining device included
for all circuits together/simultaneously
incl. 50l integrated tank
incl. pneumatic emptying function
with control S7 incl. included
Pgodskn Nilepfx Ahvjw
Energy saving and cooling capacity extension:
An additional glycol circuit integrated in the temperature control circuit takes over
the cooling of the consumer in a temperature range from +85°C
to +30°C. The absorbed energy is transferred to the on-site
< 20°C cold water network. The cooling capacity at a
flow temperature of +20°C: 50 kW.
This increases the cooling rate in this temperature range and saves
energy due to the lower running time of the refrigerant compressor.
(Footprint of the basic unit according to data sheet increases by approx. 0.3 m²)
Assembly in Rittal bayed control cabinet:
2x TS8 800x1000x2000 mm
1x additional, closed switch box min. 600x600x2000 mm
(for control/electrics)
Supplied via on-site or optional cooling medium supply
Flow temperature, on-site cooling brine -43°C, cooling brine requirement 7.5 m³/h continuously controlled
For cooling capacity a cooling medium must be connected!
Weight approx. 1200 kg
Type: Autotherm temperature control unit AWF 130-27/VK/6K
Sale ex location!
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Here we offer you a 6-circuit temperature control device.
Without active refrigerating machine!
According to the enclosed technical brief description:
Temperature range: -40°C ... +85°C (extended temperature range -40°C...+130°C)
increased heating power 27 kW instead of 18 kW
with 1x temperature control included in the main line
with 6x temperature measurement in the respective flow included
with 6x temperature measurement in the respective return included
with 6x volume flow and pressure measurement in the respective flow included
with 6x volume flow and pressure control included
1l/min ... 12 l/min and 0.1 bar ... 3 bar
incl. release control
incl. FU-controlled pump in the main line
incl. 6x 3-way valve
with 6x additional overflow valve 2 ... 12 bar adjustable included
preset to 2,4 bar
with filling and draining device included
for all circuits together/simultaneously
incl. 50l integrated tank
incl. pneumatic emptying function
with control S7 incl. included
Pgodskn Nilepfx Ahvjw
Energy saving and cooling capacity extension:
An additional glycol circuit integrated in the temperature control circuit takes over
the cooling of the consumer in a temperature range from +85°C
to +30°C. The absorbed energy is transferred to the on-site
< 20°C cold water network. The cooling capacity at a
flow temperature of +20°C: 50 kW.
This increases the cooling rate in this temperature range and saves
energy due to the lower running time of the refrigerant compressor.
(Footprint of the basic unit according to data sheet increases by approx. 0.3 m²)
Assembly in Rittal bayed control cabinet:
2x TS8 800x1000x2000 mm
1x additional, closed switch box min. 600x600x2000 mm
(for control/electrics)
Supplied via on-site or optional cooling medium supply
Flow temperature, on-site cooling brine -43°C, cooling brine requirement 7.5 m³/h continuously controlled
For cooling capacity a cooling medium must be connected!
Weight approx. 1200 kg
Type: Autotherm temperature control unit AWF 130-27/VK/6K
Sale ex location!
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Didaftarkan sejak: 2012
Hantar permintaan
Telefon & Faks
+49 2861 ... iklan
Iklan anda telah berjaya dipadamkan
Berlaku ralat