Bank Beban 1200 kWAptis
APS1200
Bank Beban 1200 kW
Aptis
APS1200
FCA VB ditambah cukai perkhidmatan
€35,000
Tahun pembuatan
2026
Keadaan
Terpakai
(berfungsi sepenuhnya)
Lokasi
Pula 

Data asas
- Nama mesin:
- Bank Beban 1200 kW
- Pengeluar:
- Aptis
- Model:
- APS1200
- Tahun pembuatan:
- 2026
- Keadaan:
- hampir baru (terpakai)
- Fungsi:
- berfungsi sepenuhnya
Harga & Lokasi
FCA VB ditambah cukai perkhidmatan
€35,000
- penyewaan:
- adalah mungkin
- Lokasi:
- Pula, Kroasia

Hubungi
Butiran teknikal
Dimensi dan berat
Berat keseluruhan:
1,300 kg
Jumlah panjang:
1,800 mm
Lebar keseluruhan:
1,470 mm
Jumlah ketinggian:
2,170 mm
Dokumentasi dan pensijilan
Penandaan CE
Butiran tawaran
- ID iklan:
- A23348348
- Kemas kini:
- terakhir pada 17.11.2026
Penerangan
For sale or rent: Outdoor resistive load banks (2 units are available) with a rated capacity of 1200 kW at 400 V AC, three-phase with neutral, 50/60 Hz. The unit provides a purely resistive load (power factor 1) and is designed for continuous duty in a weatherproof enclosure, including operation outdoors in rain.
The load is built up from 11 switchable steps (25 + 25 + 50 + 50 + 50 + 100 + 100 + 200 + 200 + 200 + 200 kW), which allows any value from 25 kW to 1200 kW to be set in 25 kW increments. Step tolerance is ±5 %, overall load tolerance ±3 %.
The load bank can be operated locally from the control panel or remotely via Modbus. Each load step, fan supply and load confirmation can be controlled over Modbus RTU (RS485/RS232) or Modbus TCP (RJ45), and status, alarms and measured values are available for monitoring. This makes the unit suitable both for classic generator testing and for integration into SCADA, energy management or virtual power plant systems as a controllable load.
A built-in class 0.5 multifunction meter displays voltage, current, active power and frequency in real time. The control system is based on a Siemens PLC, with Schneider contactors and Miro fuses.
Typical applications:
• Load testing and commissioning of diesel and gas generator sets
Iisde Akvd Ropfx Aipji
• Testing of UPS systems and other power sources
• Periodic loading of standby generators to prevent wet stacking
• Controllable load for grid balancing services (e.g. aFRR) and flexibility applications
Protection functions:
• Emergency stop with immediate unloading (fans keep running for cool-down)
• Overtemperature, overvoltage and insufficient airflow protection with automatic unloading and audible/visual alarm
• Fan interlock – load cannot be applied unless cooling fans are running
• Automatic fan phase-sequence correction
• Fuse short-circuit protection and enclosure earthing terminal
The load is built up from 11 switchable steps (25 + 25 + 50 + 50 + 50 + 100 + 100 + 200 + 200 + 200 + 200 kW), which allows any value from 25 kW to 1200 kW to be set in 25 kW increments. Step tolerance is ±5 %, overall load tolerance ±3 %.
The load bank can be operated locally from the control panel or remotely via Modbus. Each load step, fan supply and load confirmation can be controlled over Modbus RTU (RS485/RS232) or Modbus TCP (RJ45), and status, alarms and measured values are available for monitoring. This makes the unit suitable both for classic generator testing and for integration into SCADA, energy management or virtual power plant systems as a controllable load.
A built-in class 0.5 multifunction meter displays voltage, current, active power and frequency in real time. The control system is based on a Siemens PLC, with Schneider contactors and Miro fuses.
Typical applications:
• Load testing and commissioning of diesel and gas generator sets
Iisde Akvd Ropfx Aipji
• Testing of UPS systems and other power sources
• Periodic loading of standby generators to prevent wet stacking
• Controllable load for grid balancing services (e.g. aFRR) and flexibility applications
Protection functions:
• Emergency stop with immediate unloading (fans keep running for cool-down)
• Overtemperature, overvoltage and insufficient airflow protection with automatic unloading and audible/visual alarm
• Fan interlock – load cannot be applied unless cooling fans are running
• Automatic fan phase-sequence correction
• Fuse short-circuit protection and enclosure earthing terminal
Dokumen
Pembekal
Nota: Daftar secara percuma atau log masuk, untuk mengakses semua maklumat.
Kali terakhir dalam talian: minggu lepas
Didaftarkan sejak: 2025
1 Iklan dalam talian
Hantar permintaan
Telefon & Faks
+385 98 2... iklan
Iklan anda telah berjaya dipadamkan
Berlaku ralat




























































