Applied Biosystems ViiA7 mesin PCR masa nyataApplied
Biosystems ViiA7
Applied Biosystems ViiA7 mesin PCR masa nyata
Applied
Biosystems ViiA7
VB ditambah cukai perkhidmatan
€8,500
Keadaan
Terpakai
Lokasi
Borken 

Data asas
- Nama mesin:
- Applied Biosystems ViiA7 mesin PCR masa nyata
- Pengeluar:
- Applied
- Model:
- Biosystems ViiA7
- Keadaan:
- terpakai
Harga & Lokasi
VB ditambah cukai perkhidmatan
€8,500
- Lokasi:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hubungi
Butiran tawaran
- ID iklan:
- A22150267
- Nombor rujukan:
- 23464
- Kemas kini:
- terakhir pada 15.10.2026
Penerangan
Applied
Type: Applied Biosystems ViiA7
Biosystems ViiA7
Specifications:
Block change from the front of the instrument in less than 1 minute; no secondary tools required
Supported applications: Standard curve, comparative CT, genotyping, presence/absence, HRM, melting curve
Temperature uniformity: ±0.5 °C, within 30 seconds after reaching the target temperature
Run time: ~35 min for 96/384-well blocks with Applied Biosystems® Fast Master Mix
Supported blocks and volumes: 96-well standard (10–100-μl reactions)
96-well Fast (10–30 μl reactions) • 384-well (5–20 μl reactions)
TaqMan® Array Micro Fluidic Cards (~1 μl reactions)
Detectable sensitivity: up to 1 copy • Excitation/detection wavelengths: 6 excitation (450–670 nm)
6 emission (500–720 nm) • Dynamic range: Up to 9 logs linear dynamic range
Resolution: Detects only 1.5-fold changes in target quantities in a singleplex reaction
21 CFR p11 Enablement: Security, audit, and e-signature functions for instrument data
Automation: Includes plate loading arm with barcode (distribution, service, and support provided by Life Technologies)
Remote notification: Notifies the user via email when the run is started, stopped, or aborted
Data export format: Fully configurable by the user
Description:
Applied Biosystems Real-time PCR ViiA7.
Ideal for performing real-time PCR with medium to high throughput.
Interchangeable blocks for 96-well, Fast 96-well, and 384-well plates, as well as TaqMan Array Cards. Fast block change.
Touchscreen interface.
2x Ethernet connection. 2x USB connection.
1x RS 232 connection. 2x connection on the display.
Weight: 67 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in technical data and information are subject to change!)
Gjdozd Ud Nepfx Alteuh
We will gladly answer any further questions you may have by phone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Type: Applied Biosystems ViiA7
Biosystems ViiA7
Specifications:
Block change from the front of the instrument in less than 1 minute; no secondary tools required
Supported applications: Standard curve, comparative CT, genotyping, presence/absence, HRM, melting curve
Temperature uniformity: ±0.5 °C, within 30 seconds after reaching the target temperature
Run time: ~35 min for 96/384-well blocks with Applied Biosystems® Fast Master Mix
Supported blocks and volumes: 96-well standard (10–100-μl reactions)
96-well Fast (10–30 μl reactions) • 384-well (5–20 μl reactions)
TaqMan® Array Micro Fluidic Cards (~1 μl reactions)
Detectable sensitivity: up to 1 copy • Excitation/detection wavelengths: 6 excitation (450–670 nm)
6 emission (500–720 nm) • Dynamic range: Up to 9 logs linear dynamic range
Resolution: Detects only 1.5-fold changes in target quantities in a singleplex reaction
21 CFR p11 Enablement: Security, audit, and e-signature functions for instrument data
Automation: Includes plate loading arm with barcode (distribution, service, and support provided by Life Technologies)
Remote notification: Notifies the user via email when the run is started, stopped, or aborted
Data export format: Fully configurable by the user
Description:
Applied Biosystems Real-time PCR ViiA7.
Ideal for performing real-time PCR with medium to high throughput.
Interchangeable blocks for 96-well, Fast 96-well, and 384-well plates, as well as TaqMan Array Cards. Fast block change.
Touchscreen interface.
2x Ethernet connection. 2x USB connection.
1x RS 232 connection. 2x connection on the display.
Weight: 67 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in technical data and information are subject to change!)
Gjdozd Ud Nepfx Alteuh
We will gladly answer any further questions you may have by phone.
Iklan ini diterjemahkan secara automatik. Mungkin terdapat kesilapan terjemahan.
Hantar permintaan
Telefon & Faks
+49 2861 ... iklan
Iklan anda telah berjaya dipadamkan
Berlaku ralat